학술대회 안내 사전등록 안내 초록등록 안내 초록등록/관리 숙박및교통 안내


мȸ ǥ ʷ

ǥ : ȣ - 500774   105 
Physiologic evaluation of myocardial bridging: A new analysis for an old disease
서울대학교 의과대학 내과학 교실, 서울대학교병원 순환기 내과
구본권, 서정원, 김용석, 이해영, 강현재, 김효수, 오병희, 박영배
Background: Myocardial bridging is the most common congenital coronary anomaly. It is infrequently associated with myocardial ischemia, however, it is difficult to assess the functional significance of this lesion due to its dynamic nature. We performed this study to assess the hemodynamic relevance of myocardial bridges using a pressure wire. Methods: From Jan 2004 to Jul 2006, 24 patients with lone myocardial bridging lesions were consecutively enrolled (systolic compression >50% by visual estimation). Baseline angiogram was obtained after intracoronary nitroglycerine administration and angiographic data of diastolic and systolic phases were obtained. Then fractional flow reserve (FFR) and pressure parameters were measured. Diastolic FFR was calculated by off-line analysis. Cut-off values for functional significance of FFR and diastolic FFR were 0.75 and 0.76. Dobutamine stress–FFR (DS-FFR) was performed with intravenous dobutamine infusion while keeping the pressure wire across the lesion (n=13). Hyperemia was induced by intracoronary adenosine infusion. Results: Mean age was 60±9 years and 63% were male. Baseline systolic percent stenosis and lesion length of myocardial bridging were 70±16% and 24±7mm. Baseline FFR was 0.92±0.05 and diastolic FFR, 0.89±0.07 (p=0.006). No lesion was functionally significant according to baseline FFR/diastolic FFR. After dobutamine infusion, percent stenosis and lesion length were aggravated and diastolic FFR was lowered. However, FFR was not changed (Table). Two lesions became functionally significant after dobutamine infusion. Conclusion: Dobutamine increased the morphologic and functional significance of myocardial bridging. Diastolic FFR should be used in functional assessment of myocardial bridging.

Baseline

Post-Dobutamine

P value

Percent stenosis

66±13%

85±9%

0.002

Lesion length

23±7mm

26±7mm

0.05

FFR

0.92±0.05

0.91±0.06

0.08

Diastolic FFR

0.89±0.07

0.83±0.11

0.007



[ư]